Analog Setup - Test LP - Analogue Productions
If you really want to know your analog chain - not just approximately - you need a test LP. And if you need a test record, you need this one. The Ultimate Analogue Test LP from Analogue Productions is the result of a collaboration between Barry Wolifson of Sterling Sound New York and Clark Williams, Analogue Productions' own audio expert: both had the same idea at the same time, and both wanted the same thing - a test record that makes no concessions. No cannon thunder, no typewriters, no folkloristic test signals from the 1970s. Instead: precise, modern, purpose-driven - each track with a clearly defined measurement goal.
The result is a record that Harry Pearson, the legendary founder of The Absolute Sound, considers indispensable - and which Feickert Analogue, VPI Industries and leading mastering engineers in the industry have called the new reference among test records. Cut on a Neumann VMS 80 at Sterling Sound, pressed at Quality Record Pressings on 180g virgin vinyl - the production quality of the record itself is no coincidence, but a prerequisite: a test record that does not lie perfectly flat cannot deliver reliable measurement results.
TAS Editors' Choice
The Absolute Sound Editors' Choice Award - described by Harry Pearson as indispensable for every analog enthusiast
Sterling Sound / QRP
Cut on Neumann VMS 80 at Sterling Sound NY - pressed at Quality Record Pressings on 180g Virgin Vinyl
16 test tracks
Azimuth, VTA, anti-skating, frequency response, synchronization, bearing scratching - each track with clearly defined measurement target
What makes this test record different
Previous test plates were designed to test a wide range of equipment - and contained a lot that is simply irrelevant to the specific task of turntable calibration. The Ultimate Analogue Test LP focuses exclusively on turntables and cartridges. Each of the 16 tracks has a precisely defined purpose, and many - as the makers explicitly point out - can be used in several different ways.
Of particular note: Track 1 provides the 1 kHz reference tone at 7 cm/s mono (in phase, lateral) - the NAB-OVU standard reference level, which has been the industry standard since 1964, replacing the obsolete RCA 5 cm/s level. That this reference tone is recorded correctly is the basic prerequisite for all other measurements to be meaningful. Harry Weisfeld, founder of VPI Industries, let it be known after receiving the test record that the synchronization stability of his turntables had previously exceeded the limits of available test records - this is the first one that can keep up.
The Pink Noise tracks on side B have a double benefit that many users are not aware of: they are not only used to check the channel balance, but can also be used to demagnetize the cartridge and to loosen the cantilever suspension on new systems - we recommend playing them several times after every 300 hours of playing. The final silent groove is the most honest test signal of all: Absolutely nothing should come out of the speakers during playback - and a gentle tap on the rack should show how good the decoupling of the turntable really is.
Track list & measurement purpose
| Side A |
| A1 |
1 kHz Reference Tone (Mono) |
Basic reference for all measurements - 7 cm/s, NAB OVU standard. Channel balance and azimuth basic check |
| A2 |
1 kHz Reference Level (Left Only) |
Azimuth adjustment: Align the needle tip exactly vertically in the groove |
| A3 |
1 kHz Reference Level (Right Only) |
Azimuth adjustment: equalize the output level of both channels |
| A4 |
1 kHz Reference Tone (-20 dB) |
Reference for high-frequency adjustment - RIAA high-frequency EQ calibration |
| A5 |
10 kHz Reference Tone (-20 dB) |
Adjust high-frequency EQ until level corresponds to track A4 |
| A6 |
1 kHz - 20 kHz Sweep (-20 dB) |
Frequency response analysis tweeter - level should remain constant across all frequencies |
| A7 |
1 kHz - 20 Hz sweep (0 VU) |
Low frequency adjustment - RIAA low frequency EQ calibration of the phono amplifier |
| A8 |
100 Hz Reference Tone (0 VU) |
Reference low frequency - bass range EQ calibration |
| A9 |
VTA Adjust |
Vertical Tracking Angle - precise adjustment of tonearm height and needle tilt |
| A10 |
Standard Wow & Flutter Test (3150 Hz) |
Synchronization measurement - industry standard 3150 Hz tone for wow & flutter analysis |
| Page B |
| B1 |
Anti-skate test (315 Hz, sweep 0 - +12 dB) |
Precise adjustment of anti-skating - rising level until break-off indicates optimum setting |
| B2 |
Pink noise (lateral) |
Channel balance - pickup demagnetization - recording of new cantilever suspensions |
| B3 |
Pink Noise (Vertical) |
Vertical pickup demagnetization - recording - recommended after every 300 hours of playing time |
| B4 |
1 kHz Reference Level (Out-of-Phase) |
Phase correction - signal must cancel out to zero in mono. Remaining signals show distortions or phase errors |
| B5 |
1 kHz - 10 Hz sweep (-20 dB) |
Resonance analysis tonearm/cartridge - peaks and dips show resonance frequencies of the interface |
| B6 |
Silent groove |
Bearing scratching and isolation - nothing should be heard from the speakers during playback |
| Producer |
Barry Wolifson (Sterling Sound, NYC) - Clark Williams (Analogue Productions) |
| Mastering & Cutting |
Sterling Sound, New York City - Neumann VMS 80 cutting machine |
| Pressing |
Quality Record Pressings (QRP) - 180g Virgin Vinyl |
| Label |
Analogue Productions |
| Awards |
TAS Editors' Choice Award - Recommended by Harry Pearson, Dr. Christian Feickert, Harry Weisfeld (VPI) |
| Tracks |
16 (A: 10 - B: 6) |